2) You need to be on the mud-logging site with the Bloodhound.
3) There must be appropriate power to the trailer (120VAC).
4) If you are using WITS, this article assumes that the WITS system is setup and showing
the proper starting depth (for example: "100 feet" as oposed to "24,000 feet").
5) Some of the external links work on the premise that you have a working connection to
the Internet - it is therefore strongly recommended that you have access to the
Internet from an on-site computer.
TOOLS AND MATERIALS:
1) SAMPLE LINE: For rig-up of your sample line, you need to provide inlet sample line (commonly
1/4" poly line - enough to make the full run), a bubble jar and dropout jar, a dry-rite column,
and adequate connectors/pass-throughs/grommets to assemble the line and run it inside the
mud logging trailer.
2) OPTIONAL - TOOLS: The following tools are strongly recommended but not required:
a) BUTANE CIGARETTE LIGHTER: Useful with running lighter tests, trap test, and chromat
lighter tests.
b) PHILLIPS-HEAD SCREWDRIVER - MEDIUM: This is used if you need to get inside the
Bloodhound to replace a pump, etc.
c) POCKET KNIFE: Useful for quick connection changes, rig-up, etc. regarding poly line.
d) DUCT TAPE: Useful in securing leaky connections, etc.
3) OPTIONAL: If you are connecting the Bloodhound to a WITS system, you will need a
RS/232 9-pin NULL Modem cable.
4) OPTIONAL: If you are connecting the Bloodhound to the Internet via a Local Area
Network (LAN), then you will need a functioning LAN and an extra RJ-45 Ethernet cable.
HOW-TO:
This section covers unpacking the Bloodhound, making sure all of the materials are present,
hooking up the external filters, rigging up WITS (or a geolograph), rigging up the poly line inlet
and exhaust, and connecting the Bloodhound to the Internet.
1) UNPACK THE BLOODHOUND: The Bloohound will arrive in a custom-padded, soft-sided
suitcase. Remove the accesory filters, and lift the Bloodhound straight out of the suitcase
to remove it. Inspect the Bloodhound to make sure all of the components are in good
condition, and that all of the accesories provided with the Bloodhound are included and
in good condition. For more information on what comes with the Bloodhound, consult the
article entitled, -- What comes with the Bloodhound and what I need to Provide in the section --
2) CHOOSE A LOCATION FOR THE BLOODHOUND: The following suggestions for the kind of
environment in which you setup the Bloodhound are recommended:
a) Setup the Bloodhound in a relatively dust-free location (such as a mud-logging trailer)
where it can be powered by 120VAC power, and where the sample and exhaust lines
can be easily plumbed to the outside of the building.
b) OPTIONAL: If you will be using the GPRS Radio Antenna option to connect the
Bloodhound to the Internet, make provisions to run the GPRS antenna line to the outside
of the building - preferrably to the roof.
c) OPTIONAL: If you will be using a computer on which you will be running the iBall Gas
Chart software, this will need to be located within six (6) feet of the Bloodhound.
An example of a typical Bloodhound installation inside of a mud-logging trailer is shown below:
3) RIG UP THE SAMPLE INLET LINE: The sample inlet line is generally constructed of 1/4"
Poly line and has a number of items in the line. It is strongly recommended that you rig up
your sample line with the following (NOTE: For more detailed informaiton on one of the most
common rig-up, see the article entitled, -- Rigging up the Bloodhound - Recommended Apparatus --
end of this page - or click the "Article Help" icon below the list of items that follows).
a) POLY LINE: Enough 1/4-inch poly line to make the run from the Bloodhound to the trap
(1/4" is strongly recommended, but other diameters can be used). This is generally
available at most hardware and home improvement stores.
b) POLY LINE CONNECTORS: Sometimes larger poly line works, sometimes actual
connectors are used.
c) BUBBLE JAR: A bubble jar with anti-freeze or some other non-contaminant compound
is recommended near the trap for troubleshooting purpose.
d) DROPOUT JAR: A drop-out jar is like a bubble jar, but is installed very close to the
Bloodhound.
e) DRY-RITE COLUMN: A column of dessicant that is placed near the Bloodhound to avoid
moisture entering the Bloodhound.
4) RIG-UP THE EXHAUST: This is critical - rig-up the exhaust line from your Bloodhound to
a point well outside of the mud-logging shack. The type of line is less critical than that
used in the inlet, but it must seal, and it must remain obstruction-free.
NOTE: This must be done for basic safety, so do not forget this step.
5) CONNECT YOUR BLOODHOUND TO WITS: You can optionally connect your Bloodhound
to WITS via two methods. The most common method is via an RS/232 9-pin NULL Modem
cable. If you are using Pason, you can connect using the Pason RS/422 "Blue Cable". You
need to know which WITS system you are using, and may need to change the values in a
few of the Bloodhound's registers to get the Bloodhound and the WITS computer to "sync".
For more information on connecting your Bloodhound to a WITS system, see the article
link entitled, -- Connections - Hooking up WITS to the Bloodhound -- in the "OTHER ARTICLES
OF INTEREST
below:
6) STARTING DEPTH: There are two ways to setup starting depth. If you are using a
geolograph, you manually set the starting depth on the Bloodhound - if you are using a
WITS system, you need to make sure that the WITS system is fully setup, and is currently
showing the start depth of the well or sidetrack:
a) GEOLOGRAPH - SETTING STARTING DEPTH: If you are using a geolograph, you need
specify your starting depth by setting it in the "SETUP" menu on the Bloodhound. If
you do not know how to do this, consult the "Video Help" icon below. NOTE: To use
the method of setting the depth (Gas Chart) in this video, you will need to have
completed step nine (9) below on installing and setting up Gas Chart:
b) WITS - STARTING DEPTH: When using WITS, the WITS system needs to be
initialized with a starting depth like any measurement device. If you do not have the
correct starting depth before proceeding to the next step below, you will create a
database with flawed data from the start. You need to make sure that the WITS
system is showing the proper "starting" depth of the hole before starting a new
Job Number on the Bloodhound. If you have completed step five (5) above and
have a successful connection to WITS, you can see the depth that WITS is sending
to the Bloodhound by looking at the LCD screen on the face of the Bloodhound in the
location shown in the figure below. Ensure this is the start depth before attempting
step seven (7) below:
7) SET A NEW JOB NUMBER ON THE BLOODHOUND: Setting a new Job Number on the
Bloodhound has the impact of telling the Bloodhound that it's starting a new hole, and
that it should start a new master database. NOTE: The "database" on the Bloodhound
and the "database" in Gas Chart are two completely separate entities. You can start
new databases in Gas Chart all you want and it will have no impact on the Bloodhound.
Also, starting a new Job Number on the Bloodhound will not erase or tamper with the
database in Gas Chart. However, failing to start a new Job Number on the Bloodhound
at the beginning of a well or hole will cause the Bloodhound's database to consist of
well data from two different holes and immediately creates a situation where recovering
data from the well via iBallRemote.com or the Bloodhound's master database is next to
an impossibility.
You create a new Job Number on the Bloodhound by accessing the Setup Menu (the
up and down arrow keys on the face of the Bloodhound). For more information on how
to do this, consult the article link entitled, -- How to (Locally) Set a New Job Number on the Bloodhound --
8) ZERO THE TOTAL GAS: While the Bloodhound needs no calibration due to the sensor array
type (infra-red or IR), you will still need to zero the gas once the Bloodhound has been
initially setup. Make sure the temperature in the environment in which the Bloodhound will
be running has stabilized. A good rule of thumb is once the temperature has stabilized, let
the Bloodhound run for an hour or so prior to zeroing it. If you know how to zero the total
gas number on the Bloodhound, go ahead and zero it now. If you are not familiar with how
to don this, consult the article link entitled, -- How to Re-Zero the Total Gas Units on the Bloodhound
9) SETUP THE GAS CHART COMPUTER: While optional, it is strongly recommended that you
connect an on-site computer to the Bloodhound via a USB Printer Cable. This will alow you
to locally run Gas Chart software, and gives you access to make changes to critical
Bloodhound settings, perform ANSI Standard LAS file exports, configure Lag Depth and much
much more. There are three parts involved in doing this. First, setting up the USB drivers
for the Bloodhound, second, making the physical connection with the USB Printer cable, and
third, installing Gas Chart Software:
a) INSTALL THE BLOODHOUND USB DRIVERS: For more information on connecting your
Bloodhound to a local computer via the USB Printer Cable, see the article link entitled,
-- Connecting your Computer to the Bloodhound via USB Printer Cable
b) PLUG THE USB PRINTER CABLE BETWEEN THE BLOODHOUND AND COMPUTER:
WARNING: Do *not* plug this cable in until *after* you have installed the USB
drivers for the Bloodhound as mentioned in step (a) above. For more information on
installing these drivers, click the icon below:
c) INSTALL GAS CHART SOFTWARE: After the USB connection is functioning properly,
you can safely install Gas Chart. There is a copy of the installation package on the
USB Flash drive which is plugged into the face of the Bloodhound (if you remove this,
make sure you return it EXACTLY as you found it - same slot, same direction). You can
also download a fresh copy of Gas Chart from the iBall Instruments web site's "Downloads"
section at https://iballinst.com/download For more information on downloading and
installing the Gas Chart Software, you can consult the article link at the end of this page
entitled, -- How to Download and Install iBall Instruments Gas Chart Software--
d) START A NEW DATABASE IN GAS CHART: After you have either set or verified you have
the correct depth, and after you have a new Job Number on the Bloodhound, and after
you have installed Gas Chart, you now have to start a new database in Gas Chart. This is
done from the "Gas Chart Control Box". Click the "Start New Data Base" button, choose a
directory in which to save the file, give it a unique name, and save it. The chart will go blank
indicating you have successfully done this.
CONFIGURING OPTIONS AND SETTINGS:
This section is completely optional and outlines the most common options that are either the
result of special hardware (such as the iBall Instruments DC Cavitator) or which are included with
the Bloodhound but not turned on by default (such as measurement of H2S).
1) IBALL DC CAVITATOR: The iBall Instruments DC Cavitator is a low-voltage agitator that
can be run directly from a power outlet on the Bloodhound. If you already know how to
do this, make this connection now. If you are not familiar with this connection, consult the
article link entitled, -- Connections - Powering the iBall Instruments DC Cavitator from the Bloodhound --
2) TURNING ON THE H2S SENSOR: A commoon option used on the Bloodhound is its ability
to measure H2S; however, by default this option is not turned on when the Bloodhound
arrives. To turn this option on, you will need to access Register 41 in the Setup Menu on
the Bloodhound, and set it to one (1). Also, you will want to zero the H2S as well. If you
do not know how to do this, consult the article link entitled, -- How to set the Bloodhound
to measure H2S (Local) --
Congratulations! You have connected your Bloodhound to the Internet via Ethernet!